Skip to Content
AdvaSaf Site
  • Services & Capabilities

    Services


    Contact Assembly Testing CapabilitiesTesting Services SterilizationGlobal Distribution

    Sterilization


    Steam Ethylene Oxide Chlorine Dioxide Gamma E-Beam Hydrogen Peroxide
    Follow us
  • Products
    • Non-Medical
  • News
    • Events
    • Blogs
  • Store
  • About Us
    • Why work with us
    • The Advasaf Story
    • Founder and CEO
    • Business Development Executive
    • Quality Assurance Executive
  • 0
  • 0
  • +1 262-394-6898
  • Contact Us
AdvaSaf Site
  • 0
  • 0
    • Services & Capabilities
    • Products
      • Non-Medical
    • News
      • Events
      • Blogs
    • Store
    • About Us
      • Why work with us
      • The Advasaf Story
      • Founder and CEO
      • Business Development Executive
      • Quality Assurance Executive
  • +1 262-394-6898
  • Contact Us
U.S. Patent Pending

Precision Synthetic Injection Training Without Biological Hazards or Electronic Dependencies

A purely mechanical replication system for clinical volumizing procedures, delivering authentic haptic resistance and real-time visual feedback.

AdvaSaf Simulate replicates the physical mechanics, form factor, and tactile feedback of commercial medical syringes and high-viscosity injectable fillers. It operates entirely through tuned physical mechanics, without electronics, sensor arrays, external screens, or light-emitting needles. Clinicians can repeatedly practice laryngeal voice augmentation, deep facial volumizing, and mucosal reconstruction without biohazard protocols, animal or cadaver tissue limits, or patient liability.

Synthetic head and neck anatomy for AdvaSaf Simulate injection training
Clinical Risk

Practice the Force Before the Procedure

"Airway obstruction results from aggressive vocal fold injection, over-injection, or laryngeal edema from trauma and manipulation of the larynx."

Standard warning from commercial laryngeal injectable instructions for use, including Prolaryn Plus and Renu Voice.

Commercial volumizing implants, including calcium hydroxylapatite microspheres and carboxymethylcellulose gels, require significant extrusion pressure through fine needles or long transoral shafts. Inexperienced technique can produce a sudden pressure drop, over-injection, superficial placement, or tissue trauma that leads to glottic swelling and airway compromise.

AdvaSaf Simulate is a non-patient, zero-risk bench for that same mechanical problem. Repeated practice builds muscle memory for smooth plunger control, a uniform extrusion rate, correct needle depth, and precise bolus volume before the clinician enters the operating room.

Training System

What AdvaSaf Simulate Changes

Translucent tissue layers showing injection depth on an AdvaSaf Simulate trainer

Direct Injection Depth Visualization

Optically clear and translucent tissue layers show needle-tip placement, bolus formation, and injection depth while the trainee is still on the syringe.

Non-electronic mechanical syringe for haptic injection training

Non-Electronic Mechanical Design

Break-loose and glide resistance come from the hydrogel and the syringe, not from sensors or software. The trainer stays a physical instrument the clinician can rehearse with anywhere.

White and blue viscoelastic hydrogel syringes for AdvaSaf Simulate

White and Blue Hydrogels

Syringe systems use specific viscoelastic hydrogels to mimic the viscosity of medical-grade volumizers. Blue is for depth tracking. White is for high contrast.

Readymade Offerings

Gels, Syringes, Needles, and Anatomy

Customers can start with a configured training set or buy formulations, delivery hardware, needles, and anatomical modules separately.

AdvaSaf Simulate Blue translucent gel compared with White opaque hydrogel

Hydrogel Formulations

AdvaSaf Simulate Blue. A translucent blue viscoelastic gel. The color is visible through clear anatomical layers, so the trainee can confirm needle-tip placement, bolus shape, and injection depth in real time.

AdvaSaf Simulate White. An opaque white viscoelastic gel. The high-contrast appearance stands out against dark or colored accessories, surgical scopes, and internal landmarks.

Syringe Systems

Pre-filled or refillable hardware is available in standard 2.5 mL syringes and commercial BD 3 mL luer lock syringes.

Custom 1.5 mL CaHA-analog syringes match the barrel geometry, friction, and push-force kinetics of commercial calcium hydroxylapatite and heavy bulking agents, including Radiesse (Merz Aesthetics), Prolaryn Gel and Prolaryn Plus (Merz Aesthetics), and Renu (Cytophil). Paired needle hardware is calibrated for equivalent extrusion, typically 25 N to 44.5 N.

Clinical-analog syringes and needles, including a 1.5 mL CaHA analog syringe
njection push force calibration from 5 N to 44.5 N for AdvaSaf Simulate

Calibrated Needles

Needle accessories are the same geometries used in benchtop push-force benchmarking, so flow resistance matches the clinical comparison.

Superficial and dermal. 25G to 30G fine needles, 13 mm (0.5 inch), for dermal, lip, and wrinkle practice. Target push force 5 N to 9 N.

Deep tissue and mucosal. 100 mm to 150 mm needles for gynecological and submucosal reconstruction models.

Transoral laryngeal. 25G rigid or angled shafts, 200 mm to 250 mm, straight or up to 40 degrees, for vocal-fold injection laryngoplasty. Target push force 25 N to 44.5 N.

Anatomical Modules

Synthetic Anatomy on a Common Base

Optically clear or translucent silicone modules with distinct tissue boundaries and landmarks. Each module mounts on a standardized base.

Synthetic larynx module for injection laryngoplasty training

Larynx Module

Simulated vocal cords, tongue, esophagus, and rigid tracheal cartilage for percutaneous and transoral vocal-fold injection laryngoplasty.

Multi-layer facial dermal and deep malar model for volumizing practice

Facial and Deep Malar Module

Epidermis, dermis, hypodermis, muscle, and periosteum planes for mid-face volume restoration and deep bolus placement.

Synthetic hand and skin module for superficial injection training

Hand and Skin Module

Dorsal hand structures and multi-layer skin sheets for superficial spreading, subcutaneous placement, and avoiding contour irregularities.

Multi-Layer Tissue Simulation

Silicone modules for the larynx, face, and skin use optically clear layers so needle path and bolus location stay visible during practice. Layers are built as separate tissue boundaries rather than a single solid block.

E-Commerce Sets

Readymade Training Kits

Kit Gel Syringe and Needles Application and Push Force
Laryngeal Voice Injection Kit AdvaSaf Simulate Blue, translucent 1.5 mL CaHA custom syringe (Radiesse / Renu analog) plus 25G 1.5 inch or transoral shaft Vocal-fold bulking, 25 N to 44.5 N, larynx module
Facial and Dermal Volumizing Set AdvaSaf Simulate White, opaque BD 3 mL or 2.5 mL syringe plus 25G 0.5 inch (13 mm) needle Dermal and mid-face volumizing, 5 N to 9 N, face or skin module
Anatomical Training Modules and Accessories Hardware only Interchangeable needles (22G to 30G) and mounting base Larynx, face, hand, and skin. Optically clear, multi-layer silicone
Contract Manufacturing

Viscosity Tuned to the Indication

AdvaSaf Simulate is built at AdvaSaf LLC's ISO 13485:2016 certified medical manufacturing facility in Anaheim, California. The engineering team calibrates water-based cross-linked polymer hydrogels to a requested push force from 5 N to 120 N, from water-like fluids to dense, highly elastic bulking agents.

Viscosity Matching

Elastic storage modulus (G′), loss modulus (G″), apparent viscosity, and non-Newtonian yield stress set to the target indication.

Fill and Assembly

Cleanroom filling of off-the-shelf and proprietary syringe geometries, with specified needle length, gauge, and tip.

Kitting

Training kits assembled with needle accessories, anatomical blocks, and branded documentation for device firms and teaching programs.

Knowledge Base

Empirical Testing and Protocol Checks

Comparative Push Force

Bench measurements in newtons, taken with standardized push gauges, are compared with published clinical data for Radiesse, Renu, and Prolaryn Gel and Prolaryn Plus.

Procedural Walkthroughs

Demonstration material covers plunger mechanics, needle-angle navigation, and bolus deposition inside the clear anatomical modules.

Repeatability

Institutional protocols check repeat push-force consistency, including operator series on the order of n = 30, inside an allowed newton variance.

Important Disclaimer and Notice of Use

Not physician training or certification. AdvaSaf Simulate is educational simulation hardware only. It is not a formal medical training course, an accredited continuing-education program, or a physician certification.

Patent and regulatory status. Patent pending. AdvaSaf Simulate is a concept training platform for synthetic benchtop injection practice, technique instruction, and research benchmarking. It is not approved by the U.S. FDA for human or animal clinical use, diagnosis, or therapy.

Ready to Configure an AdvaSaf Simulate Training Kit?

Ask about readymade sets, anatomical modules, or a custom viscosity and syringe build.

Request a Kit
About us

Advasaf is an ISO 13485:2016 certified medical manufacturer specialized in advanced, injectable technology and pharma products. We can customize, contract manufacture, sterilize and globally distribute medical device products.

Connect with us
  • Contact us
  • contact@advasaf.com
  • +1 262-394-6898
Follow us

2026 Copyright © AdvaSaf LLC

We use cookies to provide you a better user experience on this website. Cookie Policy

Only essentials I agree